Hospitals & Multi-Specialty Clinics
OT, ICU, ventilators & life support demand 100% uptime. Generator failure means lives lost.

Total visibility into your diesel generator — electrical parameters, engine health, oil & coolant levels, and RPM — with instant alerts at every fault level.
Every sensor value streamed live to your dashboard and stored for trend analysis.
Section 1
Voltage (L-L / L-N)
3-Phase, ±0.5% accuracy
Current (Per Phase)
Up to 6000A via CT
Active Power (kW)
Import / Export tracking
Reactive Power (kVAR)
Lead / Lag detection
Power Factor
Per-phase & aggregate
Frequency (Hz)
49–51 Hz ±0.1 Hz
kWh / kVAh
Import / Export registers
THD — Harmonics
Up to 31st harmonic
Section 2
Engine RPM
Optical / magnetic pickup
Coolant Temperature
PT100 or 4–20 mA sensor
Engine Oil Pressure
0–10 bar, 4–20 mA
Fuel Level
Ultrasonic / float sensor
Oil Level
Low / OK / High status
Air Filter Differential
Differential pressure
Battery Voltage
12 V / 24 V DC
Run Hours
Tamper-proof meter
Know exactly how serious a fault is — and take the right action — before it escalates.
Each fluid is monitored with dedicated sensors and reported as a percentage or discrete level (Low / OK / High). Alerts fire independently at every threshold so you never miss a degrading trend.
Simulated live values — updates every 500 ms
From 25 kVA hospital gensets to 2 MVA data-centre standby units — if it burns diesel, WhereFy monitors it. Here is every sector where our solution is active or applicable.
4 applications
OT, ICU, ventilators & life support demand 100% uptime. Generator failure means lives lost.
MRI and CT scanner power interruptions corrupt studies and damage expensive equipment.
Temperature-controlled cleanrooms and continuous batch processes cannot tolerate power breaks.
Walk-in freezers storing vaccines and biologics require uninterrupted power below –20 °C.
5 applications
Tier-3 and Tier-4 data centres mandate N+1 generator redundancy with live fuel monitoring.
Thousands of remote tower sites need unattended genset monitoring with cellular backhaul.
Core peering infrastructure requires generator run-time logs and redundancy validation.
Centralised genset monitoring across multiple buildings on one dashboard.
On-air broadcasts and live events cannot afford generator faults during transmission.
8 applications
Assembly-line stoppage due to generator failure costs lakhs per minute in lost output.
Arc furnaces and induction heating need stable frequency and voltage from the generator.
Remote quarries and cement plants rely exclusively on gensets for operational power.
Continuous-process facilities require interlock monitoring between generator and plant DCS.
Power-intensive dyeing and weaving lines suffer costly fabric damage on abrupt shutdowns.
Wet-end process machinery and black-liquor recovery boilers demand uninterrupted power.
HACCP compliance requires cold-room temperatures logged alongside generator runtime.
Melt-line interruptions waste entire production runs and risk equipment damage.
5 applications
Emergency diesel generators at substations must start within 10 seconds of grid failure.
Hybrid sites use gensets as firm-power backup; monitor run hours to minimise fuel burn.
Water supply depends on generator-backed pumps during grid outages; dry-run protection critical.
Aeration blowers and sludge pumps need generator backup to prevent environmental violations.
Offshore platforms and wellhead facilities use gensets as primary power; fuel theft a key concern.
6 applications
Large malls run multiple gensets; centralised monitoring reduces FM team's manual rounds.
Unscheduled generator downtime during peak occupancy triggers guest complaints and revenue loss.
SEZ tenants demand 99.9% power uptime backed by auditable generator logs.
Safety-critical lighting, ATC, and cargo refrigeration require generator compliance logs.
Large-scale events require pre-event generator health checks and live fault monitoring.
In-show power failure ruins audience experience; generator must auto-transfer in < 10 s.
5 applications
Server rooms, labs, and hostels need generator monitoring with energy consumption reports.
Public service delivery requires audit-ready generator logs compliant with CPCB norms.
Mission-critical operations demand tamper-proof run-hour logs and priority alert routing.
Emergency dispatch and CCTNS connectivity must remain active during any grid failure.
Clean rooms, test chambers, and HPC clusters need uninterrupted, conditioned backup power.
5 applications
Grain dryers, milling, and cold stores at mandis rely on gensets when state grid is unreliable.
Remote pump sets powering drip and sprinkler systems need cellular-connected genset monitoring.
Multiple DG sets on large infra projects tracked from one app; auto-alerts for idle running.
Off-grid crusher units and conveyors powered by large gensets need runtime and fuel tracking.
Film shoots and outdoor events use mobile DG sets; real-time health reduces on-set downtime.
4 applications
Automated sortation systems and cold docks need DG backup monitored from the WMS dashboard.
Station signalling and platform safety systems must switch to generator within 2 seconds.
Automated fuel dispensers and POS systems need DG health alerts to avoid sales downtime.
Harbour gensets powering reefer containers need plug-in load and runtime monitoring.
If your facility runs a diesel generator, WhereFy can monitor it. Talk to an engineer — we've deployed in over 40 verticals.
Get a live demo of the WhereFy Genset Monitor on your actual generator — no obligation, no generic slides.